The unique design of the Safemount load cells offers safe, precise and simple weighing for silos, agitators and tanks. The force guiding into the double shear beam guarantees high resistance against lateral forces and thermal expansion. A totally stainless steel module is also available.The “Safemount” Load cell is very easy to install - the double shear beam load sensor can be exchanged without lifting tools. The built in rod- and stay bar security allows for some horizontal forces and thermal expansion of the vessel.For low cost weighing solutions we offer a range ”dummy load cells“ that can be combined with the ”Safemount“ or ”Baby-Safemount“ Load cells. The ”dummy load cells“ can also be used to protect the life of the load cells during mounting or welding.
Advantages
one size for capacities from 5t to 150t
no rods or stay bars required*
low vertical height
Stainless steel load cell IP 67 - module with nylon coating
Guaranteed up to 5 years
Very economic
Explosion approval according to ATEX II 1 GD EEx ia IIC T6
ATEX approval for Zone 22 does not require safety barriers
optional complete unit in stainless steel
TÜV approval (50 & 60 t)
* subject to static testing
The “Safemount” Load cell is very easy to install - the double shear beam load sensor can be exchanged without lifting tools. The built in rod- and stay bar security allows for some horizontal forces and thermal expansion of the vessel.
Capacities | 5.000 kg, 10.000 kg, 15.000 kg, 20.000 kg, 30.000 kg, 40.000 kg, 50.000 kg, 60.000 kg, 80.000 kg, 100.000 kg and 150.000 kg |
Total height | 5.000-30.000 kg= 130mm 40.000 = 145mm 50.000-60.000 = 220mm 80.000-150.000 = 280mm |
Supply voltage | 5-12 VDC, max. 15 V |
Output signal | 2 mV/V |
Linearity error | 0.05 % max. |
Hysteresis | 0.05 % |
Repeatability | 0.05 % |
Overload safety | 150% of the nominal load |
Output resistance | 700 Ohm |
Operating temperature | -10° C to 70° C |
Isolation resistance | > 2000 MOhm |
Explosion rating [opt.] | ATEX II 1 GD EEx ia IIC T6 |
The unique design of the Safemount load cells offers safe, precise and simple weighing for silos, agitators and tanks. The force guiding into the double shear beam guarantees high resistance against lateral forces and thermal expansion. A totally stainless steel module is also available.
No download.
morePrint | Website Map | Jiekes·China 2024
☞
Please send E-mail to us
Please leave a message
china@jiekes.com
☺ Please leave a message
If you want more informations, please leave a message.
Online message
☎ Please call us
If you require anything , please dial 400 freephone to call us.
4006 911718